Electron optics simulation for designing carbon nanotube based field emission X-ray source Public Deposited

Downloadable Content

Download PDF
Last Modified
  • March 20, 2019
Creator
  • Sultana, Shabana
    • Affiliation: College of Arts and Sciences, Department of Applied Physical Sciences, Materials Science Graduate Program
Abstract
  • In this dissertation, electron optics simulation for designing carbon nanotube (CNT) based field emission x-ray source for medical imaging applications will be presented. However, for design optimization of x-ray tubes accurate electron beam optics simulation is essential. To facilitate design of CNT x-ray sources a commercial 3D finite element software has been chosen for extensive simulation. The results show that a simplified model of uniform electron field emission from the cathode surface is not sufficient when compared to experimental measurements. This necessitated the development of a refined model to describe a macroscopic field emission CNT cathode for electron beam optics simulations. The model emulates the random distribution of CNTs and the associated variation of local field enhancement factor. The main parameter of the model has been derived empirically from the experimentally measured I-V characteristics of the CNT cathode. Simulation results based on this model agree well with experiments which include measurements of the transmission rate and focus spot size. The model provides a consistent simulation platform for optimization of electron beam optics in CNT x-ray source design. A systematic study of electron beam optics in CNT x-ray tubes led to the development of a new generation of compact x-ray source with multiple pixels. A micro focus field emission x-ray source with a variable focal spot size has been fully characterized and evaluated. It has been built and successfully integrated into micro-CT scanners which are capable of dynamic cardiac imaging of free-breathing small animals with high spatial and temporal resolutions. In addition a spatially distributed high power multi-beam x-ray source has also been designed and integrated into a stationary digital breast tomosynthesis (s-DBT) configuration. This system has the potential to reduce the total scan time to 4 seconds and yield superior image quality in breast imaging.
Date of publication
Resource type
Rights statement
  • In Copyright
Note
  • "... in partial fulfillment of the requirement for the degree of Doctor of Philosophy in the Curriculum in Applied Science and Engineering."
Advisor
  • Lu, Jianping
Language
Publisher
Place of publication
  • Chapel Hill, NC
Access
  • Open access
Parents:

This work has no parents.

Items